Small quantity generators and HAZWOPER applicability: FAQs
25 answers about small quantity generators and HAZWOPER applicability.
Does HAZWOPER apply to small quantity generators?
Not in most cases for routine operations. Employers that are small quantity generators or conditionally exempt (now very small quantity) generators, and not required to have a RCRA permit or interim status, are excepted from paragraphs (p)(1) through (p)(7) of 1910.120. Emergency response obligations may still apply.
Does generator status decide HAZWOPER coverage?
RCRA generator category does not by itself decide every HAZWOPER issue. The employer must evaluate whether the operation fits paragraph (p), a cleanup provision, emergency response or other OSHA standards.
Does HAZWOPER apply to very small quantity generators?
Generally not for routine waste handling. A very small quantity generator (formerly conditionally exempt small quantity generator) is excepted from the TSD facility provisions. If its employees respond to emergencies, paragraph (q) or (p)(8) may apply.
What OSHA training applies to a small quantity generator?
Small quantity generators usually need Hazard Communication training, PPE training and an emergency action plan or emergency response plan. If employees respond to releases, HAZWOPER emergency response training applies at the level of their duties.
What OSHA training does a small business that accumulates hazardous waste need?
A small business that accumulates waste for shipment typically needs Hazard Communication, PPE and emergency planning training. It needs HAZWOPER training only if employees respond to emergencies or perform other covered operations.
When does HAZWOPER apply to a generator?
HAZWOPER can apply to a generator whose employees respond to hazardous substance emergencies, perform cleanup at uncontrolled hazardous waste sites, or work at a portion of the facility that requires a RCRA permit or interim status.
What is paragraph (p)(8) and how does it apply to generators?
Paragraph (p)(8) sets emergency response requirements for TSD facilities. Excepted generators that are required by EPA or a state agency to have employees respond to emergencies, or that direct their employees to respond, are covered by (p)(8).
Can a generator avoid HAZWOPER emergency response requirements?
Yes, if employees will not respond. An employer that evacuates employees and calls outside responders, and has an emergency action plan under 29 CFR 1910.38, is exempt from the paragraph (q) emergency response requirements.
How does a generator's emergency plan affect HAZWOPER?
A facility that evacuates employees and prohibits them from helping with an emergency has different obligations from one with an employee response team. A response team needs a written emergency response plan, training at the right levels, PPE and medical surveillance for team members.
What training do employees need at a generator site with a small waste volume?
They need training on the hazards of the waste and chemicals they handle, labeling, container management and emergency procedures. EPA rules require small quantity generators to make sure employees are familiar with proper waste handling and emergency procedures.
How do EPA generator categories work?
EPA classifies generators by monthly hazardous waste generation: very small quantity generators produce 100 kilograms or less, small quantity generators more than 100 and less than 1,000 kilograms, and large quantity generators 1,000 kilograms or more (or more than 1 kilogram of acute hazardous waste).
Can a generator's category change from month to month?
Yes. Generator category is based on the amount generated in each calendar month. An episodic event or a busy month can raise a generator into a higher category, which changes its EPA requirements.
Does a change in generator category change HAZWOPER requirements?
Not directly. A generator category change mainly changes EPA requirements. OSHA requirements still depend on what employees actually do, including whether they respond to emergencies or perform cleanup operations.
Do small quantity generators need a contingency plan?
Small quantity generators must meet basic emergency preparedness requirements, including an emergency coordinator, posted emergency information and employee familiarity with procedures. Large quantity generators must have a full written contingency plan.
What should a small quantity generator do after a spill?
Follow the facility's emergency procedures. If the spill is incidental, trained employees may clean it up. If it is beyond their capability, evacuate, call outside responders and notify the emergency coordinator and any required agencies.
Who should confirm a business's generator status?
An environmental professional or the state environmental agency can help confirm generator status. An EHS professional should then map the operations to OSHA training requirements.
Does HAZWOPER apply to auto repair shops that generate hazardous waste?
Usually not for routine work. Auto shops are typically small or very small quantity generators. They need Hazard Communication, PPE and emergency planning, and HAZWOPER only if employees respond to emergency releases.
Does HAZWOPER apply to dry cleaners or print shops?
Generally not for normal operations. These businesses need Hazard Communication, PPE and emergency planning for the solvents and inks they use. HAZWOPER emergency response training applies only if employees respond to emergencies.
Can a small generator have employees clean up spills?
Yes, for incidental spills that employees can safely control with their training and equipment. For larger or unknown releases, employees should evacuate unless they are trained responders under paragraph (q).
What records should a small generator keep for employee training?
Keep records of Hazard Communication, PPE and emergency procedure training, plus any HAZWOPER training if employees respond to emergencies. EPA and state rules may also require specific generator training records.
Do state rules change generator requirements?
Yes. States with authorized RCRA programs can have stricter or broader requirements, including lower thresholds or additional training. Check the state environmental agency's rules.
What OSHA standards apply to generators besides HAZWOPER?
Common standards include Hazard Communication (1910.1200), PPE (1910.132), respiratory protection (1910.134), emergency action plans (1910.38), fire prevention plans (1910.39) and walking-working surfaces. Substance-specific standards may apply too.
Does HAZWOPER apply to a facility's waste storage area?
For a generator not required to have a RCRA permit, routine operations in the accumulation area are generally not covered by paragraph (p)(1) through (p)(7). Emergency response in that area may be covered by (p)(8) or paragraph (q).
Do employees who package waste for shipment need HAZWOPER training?
Not usually at a generator site. They do need training on hazards and PPE, and if they prepare or sign shipping papers, mark or label packages, or load hazardous materials, they need DOT hazmat employee training under 49 CFR 172.704.
What is the most common HAZWOPER mistake at small generator sites?
A common mistake is having untrained employees respond to releases beyond incidental spills. Either train a response team to the right level or plan for employees to evacuate and call outside responders.