Satellite accumulation and container management: FAQs

25 answers about satellite accumulation and container management.

Use note: These answers are general educational information, not a determination of an employer’s legal obligations. OSHA requirements depend on the operation, worker duties, exposures, and jurisdiction. Employers should review the applicable standard and site-specific conditions before assigning work.
What does satellite accumulation mean under RCRA?

A satellite accumulation area is a location at or near the point where hazardous waste is generated and under the control of the operator of that process. Federal rules for satellite accumulation are in 40 CFR 262.15.

How much hazardous waste can be kept at a satellite accumulation area?

Under federal rules, a satellite area may hold up to 55 gallons of non-acute hazardous waste, or up to 1 quart of liquid or 1 kilogram of solid acute hazardous waste. State rules can be stricter, so check before setting a site limit.

How should a RCRA satellite accumulation container be labeled?

Containers must be marked with the words "Hazardous Waste" and an indication of the hazards of the contents, such as the applicable hazard class, a GHS pictogram, an NFPA label or a hazard statement. States may require additional information.

Must satellite accumulation containers stay closed?

Yes. Containers must be kept closed except when adding, removing or consolidating waste, or when temporary venting is needed for safe operation of equipment or to prevent dangerous conditions.

Who can move waste from a satellite accumulation area?

Trained employees designated by the generator should move waste to the central accumulation area. Moving waste requires knowledge of compatibility, container condition, labeling and safe handling.

What happens when a satellite area reaches its accumulation limit?

Once the limit is exceeded, the generator must mark the container holding the excess with the date the excess began accumulating, and move it to a central accumulation area or other permitted area within three consecutive calendar days.

Does a satellite container need an accumulation start date?

Not under federal rules while it is within the satellite limit. A date is required when the limit is exceeded, and once the container is moved to the central accumulation area, the generator's accumulation time limits apply. Some states require a start date at all times.

Where can a satellite accumulation area be located?

It must be at or near the point of generation and under the control of the operator of the process generating the waste. Waste generated in one room generally should not be stored in a satellite area in a different building.

How many satellite accumulation areas can a facility have?

Federal rules do not limit the number of satellite areas. Each must meet the rules for location, control, quantity, containers and marking.

What training do employees need for satellite accumulation?

Employees should be trained on which waste goes in each container, how to keep containers closed, labeling, compatibility, how to recognize leaks or damage and whom to call when a container is full or damaged.

What type of container should be used for satellite accumulation?

Containers must be in good condition and compatible with the waste. For example, corrosive waste should not go in a metal can that it can corrode.

Can incompatible wastes be stored in the same satellite area?

Incompatible wastes must not be placed in the same container, and containers of incompatible wastes should be separated or protected so a leak cannot cause them to mix. Train staff not to mix incompatible wastes.

What should employees do if a satellite container is leaking?

Transfer the waste to a container in good condition or otherwise manage the leak according to the facility's procedures, clean up any spill and report it. Train staff to report leaks, bulging, corrosion or damaged closures immediately.

How often should satellite accumulation areas be inspected?

Federal rules do not set an inspection frequency for satellite areas, unlike central accumulation areas, which large and small quantity generators must inspect at least weekly. Many facilities inspect satellite areas weekly anyway.

Who is responsible for a satellite accumulation area?

The generator is responsible. Day-to-day control rests with the operator of the process generating the waste, who should be trained and know the rules for that area.

Can a funnel be left in a satellite accumulation container?

Only if it is a closed funnel designed to seal the container, such as a latching lid funnel. An open funnel left in the container means the container is not closed.

Does a very small quantity generator need to follow satellite rules?

Federal satellite accumulation rules in 40 CFR 262.15 apply to small and large quantity generators. Very small quantity generators have more limited requirements, but safe container management is still good practice, and states may add rules.

What is the difference between satellite accumulation and central accumulation?

Satellite accumulation is a small amount of waste at the point of generation, with limited requirements. Central accumulation is where waste is consolidated before shipment and is subject to time limits, inspections and full labeling and dating requirements.

Can satellite containers be moved between satellite areas?

Waste should be moved to the central accumulation area, not to another satellite area. Moving waste between satellite areas can violate the at-or-near-point-of-generation requirement.

How should full satellite containers be handled?

When a container is full or the limit is exceeded, date it, close it securely and move it to the central accumulation area within three consecutive days. Replace it with an empty, labeled, compatible container.

What reactive wastes need special handling in satellite areas?

Reactive, ignitable and shock-sensitive wastes need extra care, such as storage away from ignition sources, separation from incompatibles and limits on quantity. Follow the SDS and the facility's procedures.

Do satellite accumulation areas need secondary containment?

Federal satellite rules do not require secondary containment, but it is a good practice for liquids and may be required by state rules, fire codes or company policy.

Are satellite accumulation areas covered by HAZWOPER?

Routine waste collection in satellite areas at a generator site is generally not a HAZWOPER operation. A spill that requires an emergency response, or work at a permitted TSDF, can bring HAZWOPER into play.

What records are needed for satellite accumulation?

Federal rules do not require logs for satellite areas, but the generator must be able to show the areas meet the rules. Many facilities keep inspection checklists and training records to show compliance.

What are common satellite accumulation violations?

Common violations include open containers, missing or incomplete labels, exceeding the 55-gallon limit, containers in poor condition, incompatible wastes mixed together and areas not under the control of the process operator.