Air monitoring instruments and gas detector use: FAQs
25 answers about air monitoring instruments and gas detector use.
What does a four-gas meter measure at a cleanup site?
A typical four-gas meter measures oxygen, combustible gas as a percentage of the lower explosive limit (LEL), carbon monoxide and hydrogen sulfide. Models and sensors vary, so check the instrument manual.
Can a four-gas meter detect every hazard at a cleanup site?
No. A four-gas meter only detects what its sensors are designed for. It will not detect most toxic organic vapors, metals or particulates, so other instruments or sampling are needed.
How do you bump test a gas monitor before entry?
Expose the sensors to a known concentration of test gas, usually from a calibration gas cylinder, and confirm that each sensor responds and the alarms activate. Follow the manufacturer's procedure.
What is the difference between a bump test and calibration?
A bump test checks that gas reaches the sensors and alarms respond. Calibration adjusts the instrument to read accurately against a known gas concentration. Follow the manufacturer's schedule and the employer's program for both.
How often should a gas monitor be bump tested?
Many manufacturers and industry guidance recommend a bump test before each day's use. If the instrument fails, it should be calibrated or removed from service.
When is a PID useful for HAZWOPER air monitoring?
A photoionization detector (PID) is useful for screening many volatile organic compounds, tracking changes in vapor levels, finding leaks and helping define work zones. It is a common tool at cleanup sites with solvents or fuels.
Why is a PID reading not the same as a chemical concentration?
A PID responds to many ionizable compounds and usually does not identify a chemical. Readings depend on the lamp, calibration gas, response factors, humidity and interference, so a PID reading is an estimate, not a measured concentration of a specific chemical.
What is a PID response factor?
A response factor is a correction factor for a specific chemical relative to the calibration gas, usually isobutylene. Multiplying the reading by the response factor gives a better estimate of that chemical's concentration, if it is the only one present.
What gas detector should be used for unknown vapors?
For unknown vapors, sites often start with a combination of a multigas meter, a PID and sometimes a flame ionization detector, plus colorimetric tubes or samples for laboratory analysis. No single instrument identifies all unknowns.
What is a flame ionization detector?
A flame ionization detector (FID) measures many organic compounds by burning them in a hydrogen flame. It responds to compounds such as methane that a PID cannot detect, but it does not identify chemicals either.
What are colorimetric detector tubes used for?
Colorimetric tubes give a quick estimate of the concentration of a specific chemical or chemical group. They help confirm whether a suspected chemical is present but have limited accuracy and can be affected by interferences.
When should a site use personal air sampling instead of direct-reading instruments?
Personal air sampling, with lab analysis, is needed to measure a worker's actual exposure for comparison with exposure limits. Direct-reading instruments are better for real-time screening, alarms and work-zone decisions.
Why can't workers rely on one meter reading to decide a site is safe?
Hazards can change with weather, work activities, digging or opening containers. Monitoring should continue throughout the work, and no single reading guarantees a safe atmosphere.
What training do workers need to use air monitoring instruments?
Workers need training on startup checks, bump testing, sampling technique, alarm response, sensor limits, calibration and what to do when a reading is unexpected. They should practice with the actual instruments they will use.
How do you choose air monitoring instruments for a cleanup site?
Base the choice on the expected contaminants, their exposure limits, flammability, oxygen hazards and site conditions. The site safety and health plan should list the instruments, action levels and monitoring frequency.
Where should air monitoring be done on a HAZWOPER site?
Monitor in the breathing zone of workers, at the perimeter of work zones, near sources such as open excavations or drums, in low areas where vapors collect and downwind of the work.
How often should air monitoring be done on a HAZWOPER site?
The site plan should set monitoring frequency. Monitoring is typically done before entry, continuously or at set intervals during work, and whenever conditions change, such as when new containers are opened or excavation begins.
What does HAZWOPER require for air monitoring?
Paragraph (h) requires monitoring to identify IDLH conditions, exposures above limits and other dangerous conditions during initial site entry, and periodic monitoring when exposures may change. The site plan must describe monitoring frequency and types.
What should workers do when a gas monitor alarms?
Follow the site's alarm procedure: usually stop work, leave the area and report. Do not silence the alarm and continue work without authorization and evaluation by the site safety officer.
What causes false readings on gas detectors?
False readings can come from sensor cross-sensitivity, humidity, temperature changes, radio interference, sensor poisoning by silicones or lead compounds, low batteries or overdue calibration.
What are sensor poisons for combustible gas sensors?
Silicones, lead compounds, sulfur compounds and some halogenated chemicals can damage catalytic bead sensors and make them read low. If poisons may be present, bump test more often or use a different sensor type.
Can a combustible gas meter work in low-oxygen atmospheres?
Catalytic bead LEL sensors need oxygen to work correctly. In oxygen-deficient atmospheres they can read falsely low. Infrared LEL sensors do not have this limitation.
How should air monitoring results be recorded?
Record the date, time, location, instrument, readings, calibration or bump test results, weather and the person who took the readings. Records support decisions about PPE and work zones and are part of the site file.
Who should interpret air monitoring results?
Results should be interpreted by the site safety officer or another qualified person who understands the instrument limits, the contaminants and the action levels in the site plan.
Do air monitoring instruments need to be intrinsically safe?
Instruments used where flammable atmospheres may exist should be certified as intrinsically safe for the hazardous location. Check the instrument's certification and the site's hazardous area classification.