Oxygen, LEL, and alarm interpretation: FAQs
25 answers about oxygen, LEL, and alarm interpretation.
What oxygen percentage is considered oxygen deficient at work?
OSHA generally defines an oxygen-deficient atmosphere as one with less than 19.5 percent oxygen by volume. Normal air contains about 20.9 percent oxygen. Apply the correct standard and site procedure for the work.
What oxygen level is considered oxygen enriched?
OSHA's confined space standard treats an atmosphere above 23.5 percent oxygen as oxygen enriched. Enriched atmospheres greatly increase fire risk because materials ignite more easily and burn faster.
What should workers do when oxygen readings drop below 19.5 percent?
Leave the area and report the reading. Do not re-enter without supplied-air respiratory protection, such as SCBA, and the site safety officer's approval. A falling oxygen level also signals that another gas is displacing the air.
Why does a small drop in oxygen matter?
A drop from 20.9 to 19.5 percent means something is displacing the air. Even if the oxygen level is not yet dangerous, the displacing gas may be toxic or flammable, so the cause must be found.
What does LEL mean on a gas meter?
LEL stands for lower explosive limit, the lowest concentration of a flammable gas or vapor in air that can ignite. A meter reading of 10 percent LEL means the atmosphere is at one-tenth of the concentration needed to ignite.
What LEL alarm setting is used for hazardous site work?
Alarm setpoints depend on the task, applicable rule, instrument and employer policy. Many sites set the low alarm at 10 percent LEL. OSHA's confined space standard treats more than 10 percent of the lower flammable limit as a hazardous atmosphere. The site plan should set specific action levels.
What should workers do when a combustible gas meter alarms?
Follow the site procedure, which typically means stopping work, removing ignition sources if safe to do so, leaving the area and reporting. Do not silence the alarm and continue work without authorization and evaluation.
What does a common HAZWOPER LEL action level guide recommend?
Federal guidance for hazardous waste sites commonly uses 10 percent LEL as the point to continue only with caution and continuous monitoring, and 25 percent LEL as the point to withdraw because of the explosion hazard. The site plan sets the action levels for each site.
Can a four-gas meter confirm that an area is safe?
No. A four-gas meter can miss hazards outside its sensor range. A safe reading on its four sensors does not establish that all contaminants are absent, especially toxic organic vapors, metals or particulates.
How do oxygen readings affect respirator selection?
Oxygen concentration and contaminant identity affect respirator selection. Air-purifying respirators do not supply oxygen and must not be used in oxygen-deficient or IDLH atmospheres. Those conditions require SCBA or supplied air with an escape bottle.
Is an oxygen-deficient atmosphere considered IDLH?
Under OSHA's respiratory protection standard, oxygen-deficient atmospheres are considered IDLH, unless the employer shows that the oxygen level is within a range in which atmosphere-supplying respirators are not required.
What are the high and low alarm settings for a typical gas meter?
Common factory settings are a low alarm at 19.5 percent and a high alarm at 23.5 percent for oxygen, 10 percent and 20 percent LEL for combustibles, and alarms for carbon monoxide and hydrogen sulfide based on exposure limits. Employers should confirm settings match their program.
What are typical alarm settings for carbon monoxide and hydrogen sulfide?
Typical factory alarm settings are 35 ppm for carbon monoxide and 10 ppm for hydrogen sulfide, with higher second-level alarms. Check the instrument and set alarms according to the employer's program and applicable limits.
What should workers do when a hydrogen sulfide alarm sounds?
Leave the area immediately, moving upwind if possible, and report. Hydrogen sulfide can deaden the sense of smell, so workers should never rely on odor to judge whether it is still present.
What is the difference between a TWA alarm and a STEL alarm on a gas meter?
A TWA alarm warns when the average exposure over the shift approaches a limit, while a STEL alarm warns of high exposure over a short period, usually 15 minutes. Both are calculated by the instrument from readings over time.
Can an LEL reading of zero mean no flammable gas is present?
Not always. The sensor may be poisoned, the gas may not be detected well by the sensor type, oxygen may be too low for a catalytic sensor to work, or the sampling location may be wrong. Bump test the meter and sample in several locations.
What should workers do when oxygen readings rise above 23.5 percent?
Leave the area, remove ignition sources if safe and report. Oxygen-enriched atmospheres can cause clothing and materials to catch fire easily, so ventilation and the source of oxygen must be controlled before re-entry.
What causes oxygen-deficient atmospheres at cleanup sites?
Common causes include displacement by gases such as nitrogen, carbon dioxide or methane, consumption of oxygen by rusting metal, decaying organic matter or bacteria, and inert gases used in purging tanks.
Where should oxygen and LEL readings be taken?
Take readings at several heights and locations, because gases heavier than air settle in low areas and lighter gases rise. Test confined spaces from top to bottom before entry.
How often should oxygen and LEL be monitored during work?
The site plan should set the frequency, but continuous monitoring is common during work in confined spaces, excavations, tank work and any time flammable or oxygen-displacing gases may be present.
Can a gas meter alarm be silenced during work?
Workers should not silence alarms and continue working. If an alarm sounds, the cause must be evaluated by the site safety officer before work resumes.
What training should workers have on alarm interpretation?
Workers should understand what each sensor measures, the meaning of each alarm, the site action levels, sensor limitations and what to do when an alarm sounds. Practice responding to alarms during training.
Why do some gases read differently on an LEL sensor?
LEL sensors are calibrated to one gas, often methane or pentane. Other gases produce different responses, so a reading may over- or under-estimate the actual percent LEL. Correction factors from the manufacturer can help.
What does an oxygen reading tell you about toxic gas levels?
A small oxygen drop can signal a large amount of another gas. For example, each 1 percent drop in oxygen corresponds to roughly 5 percent of another gas in the air, which could be many times a toxic exposure limit.
Who sets the action levels for oxygen and LEL at a site?
The employer, through the site safety and health plan, usually prepared or approved by a qualified safety professional. Action levels should reflect the site's hazards, applicable standards and instrument limitations.